Acc. to national standards and specifications.POWERCABLES

BayEnergy®

BayEnergy® power cables

BayEnergy® CPR Eca power cable, PVC insulation, PVC sheath, acc. to DIN VDE 0276

NYY-J    1-2-cores     3-cores     3-1/2-cores     4-5-cores    multicore      |     NYY-O   1-2-cores      3-cores      3-1/2-cores     4-5-cores     multicore


BayEnergy® power cable, PVC insulation, PE sheath, acc. to DIN VDE 0276

NY2Y-J   1-multicore      |     NY2Y-O   1-multicore


BayEnergy® power cable, PVC insulation, concentric conductor, PVC sheath, acc. to DIN VDE 0276

NYCY    1-core      2-3-cores     4+1-cores (TN-S+)     5-cores     multicore      with protective conductor

NYCWY    2-3-cores     4+1/2-cores (TN-S)     4+1-cores (TN-S+)       5-cores


BayEnergy® power cable, PVC insulation, armouring, PVC sheath, acc. to DIN VDE 0271

NYFGY-J    3-cores      3+1/2-cores     4-cores      |     NYFGY-O    1-multicore

NYRGY-J    3-, 4-, 5- and multicore      |     NYRGY-O    3-, 4-, 5- and multicore


BayEnergy® power cable, XLPE insulation, PVC sheath, acc. to DIN VDE 0276

N2XY-J   1-core     3-core     3 1/2-core      4-5-core      multicore        |        N2XY-O   1-2-cores      3-cores      3 1/2-cores      4-5-cores     multicore


BayEnergy® power cable, XLPE insulation, PE sheath, acc. to DIN VDE 0276

N2X2Y-J   1-core      3-cores     3 1/2-cores     4-5-cores    multicore       |    N2X2Y-O    1-core    3-core     3 1/2-core     4-5-core     multicore


BayEnergy® power cable, XLPE insulation, concentric conductor, PVC-, or PE-sheath, acc. to DIN VDE 0276-603 or DIN VDE 0276-627

N2XCY    1-2-cores       3-cores      4-1/2-cores (TN-S)      4+1-cores (TN-S+)      5-cores     multicore

N2XC2Y   1-3-cores      4-1/2 / 4+1-cores (TN-S, TN-S+)

N2XCWY   3-cores      4-1/2-cores (TN-S)      4+1-cores (TN-S+)


BayEnergy® power cable, XLPE insulation, PE composite layer sheath, based on DIN VDE 0276-603, or VDE 0276-627

(N)2X(L)2Y-J    1-core     3-cores      3 1/2-cores      4-5-cores      multicore


BayEnergy® CPR Eca BayEnergy® CPR Eca Halogen-free power cables with special fire performance, acc. to DIN VDE 0276

N2XH-J    1-core       3-cores      3 1/2-cores      4-5-cores     multicore       |     N2XH-O    1-core       3-cores      3 1/2-cores      4-5-cores     multicore

N2XCH    1-2-cores      3-cores       4 1/2-cores, (TN-S)       4+1-cores, (TN-S+)       5-cores        multicore       |       N2XCWH    4 1/2-cores, (TN-S)      4+1-cores, (TN-S+)


BayEnergy® nonfire, Highly flame-retardant power cable with improved behaviour in case of fire, acc. to DIN VDE 0276-604

N2XH   1-core-multicore       |      N2XCH   3-core    4 1/2-cores, (TN-S)        |       N2XCWH   3-core       4 1/2-cores, (TN-S)


BayEnergy® railway power cable, copper conductor, acc. to DIN VDE 0271

N2XSY    1-core            N2XS2Y    1-core          N2XS(F)2Y    1-core

N2XSH   1-core             N2XS(F)H   1-core

NYSY   1-core


BayEnergy® nonfire, Halogen-free, highly flame-retardant cable for special applications, acc. to DIN VDE 0271

N2XSH   1-core      |      N2XS(F)H   1-core


BayEnergy® CPR Eca power distribution cables for DSTWs DB-(N)YYBY / DB-(N)YYRGY / DB-(N)YYFGY, acc. to DB DLST.038

DB-(N)YYBY-O    2 and 4-cores      |      DB-(N)YYRGY-O    2 and 4-cores      |      DB-(N)YYFGY-O    2 and 4-cores


BayEnergy® Fca halogen-free power distribution cables for DSTWs DB-(N)2X2YBY / DB-(N)2X2YRGY / DB-(N)2X2YFGY, acc. to DB DLST.038

DB-(N)2X2YB2Y-O    2 and 4-cores      |      DB-(N)2X2YRG2Y-O    2 and 4-cores      |      DB-(N)2X2YFG2Y-O    2 and 4-cores

1,8/3 kV

BayEnergy® railway power cable, acc. to IEC 60502-1, and based on DIN VDE 0271

(N)2XS2Y PE sheath   railway power cable       |        (N)2XS(F)2Y PE sheath   railway power cable
(N)2XSY PVC sheath    railway power cable       |      (N)2XSH flame retardant    railway power cable


BayEnergy® nonfire, Highly flame-retardant cable for special applications, based on DIN VDE 0271

(N)2XS(F)H     1-core      |       (N)2XSH   1-core

3,6/6 kV

BayEnergy® power cable, PVC insulation, armouring, PVC sheath, acc. to DIN VDE 0271

NYFGY   3-cores 3,6/6 kV

BayEnergy® power cable, PVC insulation, screen, PVC sheath, acc. to DIN VDE 0271

NYSY      1-core 3,6/6 kV


6/10 kV

Power cable, XLPE insulation, screen, PE sheath, acc. to DIN VDE 0276-620

N2XS2Y     6/10 kV

N2XS(F)2Y     6/10 kV

Power cable, XLPE insulation, screen, PVC sheath, acc. to DIN VDE 0276-620

N2XSY     6/10 kV


12/20kV

BayEnergy® nonfire, halogen-free and highly flame-retardant medium voltage cable, based on DIN VDE 0276-620 / DIN VDE 0276-622

Metro MV       1-3-cores 12/20 kV

Power cable, XLPE insulation, screen, PE sheath, acc. to DIN VDE 0276-620

N2XS2Y           12/20 kV

N2XS(F)2Y     12/20 kV

Power cable, XLPE insulation, screen, PVC sheath, acc. to DIN VDE 0276-620

N2XSY             12/20 kV


18/30 kV

Power cable, XLPE insulation, screen, PE sheath, acc. to DIN VDE 0276-620

N2XS2Y         18/30 kV

N2XS(F)2Y   18/30 kV

0,6/1 kV

BayEnergy® CPR Eca power cable, PVC insulation, PVC sheath, acc. to DIN VDE 0276 part 603

NAYY-J   3 1/2-cores    4-5-cores     |     NAYY-O   1-core    4-cores


BayEnergy® power cable, PVC insulation, PE sheath, acc. to DIN VDE 0276 part 603

NAY2Y-J    4-cores     |     NAY2Y-O   4-cores


BayEnergy® power cable, PVC-/XLPE insulation, concentric conductor, PVC sheath, acc. to DIN VDE 0276 part 603

NAYCWY     3-cores     4-1/2-cores (TN-S)     4+1-cores (TN-S+)     |    NA2XCWY    4-1/2-cores (TN-S)     4+1-cores (TN-S+)


BayEnergy® power cable, XLPE insulation, PVC sheath, acc. to DIN VDE 0276 part 603

NA2XY-J    1-3-cores     4-cores     |     NA2XY-O   1-3-cores     4-cores


BayEnergy® power cable, XLPE insulation, PE sheath,  acc. to DIN VDE 0276 part 603

NA2X2Y-J     1-core     3-cores     4-5-cores      |      NA2X2Y-O    1-core    3-cores     4-cores


BayEnergy® nonfire, Aluminium, based on DIN VDE 0276-604

(N)A2XH  XLPE-Insulation, halogen free, flame retardant sheath       1-4-cores


BayEnergy® railway power cable 0,6/1 kV, Aluminium, acc. to DIN VDE 0271

NA2XSY  PVC-sheath  railway power cable 0,6/1 kV

NA2XS2Y  PE-sheath  railway power cable 0,6/1 kV

1,8/3 kV

BayEnergy® railway power cable 1,8/3 kV, Aluminium, acc. to IEC 60502-1, or based on DIN VDE 0271

(N)A2XS2Y PE-sheath   railway power cable 1,8/3 kV      |      (N)A2XS(F)2Y PE-sheath   railway power cable 1,8/3 kV

(N)A2XSY PVC-sheath   railway power cable 1,8/3 kV

6/10 kV

Power cable, XLPE insulation, screen, PE sheath, acc. to DIN VDE 0276-620

NA2XS2Y      6/10 kV      |       NA2XS(F)2Y     6/10 kV

BayEnergy® power cable, XLPE insulation, screen, PVC sheath, acc. to DIN VDE 0276-620

NA2XSY       6/10 kV


12/20 kV

Power cable, XLPE insulation, screen, PE sheath, acc. to DIN VDE 0276-620

NA2XS2Y      12/20 kV      |       NA2XS(F)2Y     12/20 kV

Power cable, XLPE insulation, longitudinally and radially watertight, screen, PE sheath, acc. to DIN VDE 0276-620

NA2XS(FL)2Y        12/20 kV

Power cable, XLPE insulation, screen, PVC sheath, acc. to DIN VDE 0276-620

NA2XSY        12/20 kV

18/30 kV

Power cable, XLPE insulation, screen, PE sheath, acc. to DIN VDE 0276-620

NA2XS2Y      18/30 kV      |       NA2XS(F)2Y     18/30 kV

BayEnergy® XLPE insulated overhead lines, acc. to DIN VDE 0276-626

NFA2X     1-6-cores      1-6-cores  method B


BayEnergy® Dachständer-Anschlussleitung für VPE-isolierte Freileitungen, nach DIN VDE 0250-213

NYDY   4-cores

BayEnergy® EMC cables for TN-S systems, copper conductor, acc. to DIN VDE 0276 part 603

NYCY   4+1-cores, (TN-S+)     |     NYCWY    4 1/2-cores, (TN-S)      4+1-cores, (TN-S+)

N2XCY    4 1/2-cores, (TN-S)      4+1-cores, (TN-S+)     |     N2XCWY     4 1/2-cores, (TN-S)      4+1-cores  (TN-S+)


BayEnergy® EMC cables for TN-S systems, halogen free, flame retardant, low smoke, acc. to DIN VDE 0276 part604

N2XCH    4 1/2-cores, (TN-S)      4+1-cores, (TN-S+)    |    N2XCWH   4 1/2-cores, (TN-S)      4+1-cores, (TN-S+)


BayEnergy® EMC cables for TN-S systems, Aluminium conductor, acc. to DIN VDE 0276 part 603

NA2XCWY    4 1/2-cores, (TN-S)      4+1-cores, (TN-S+)


BayEnergy® EMV-Kabel für TN-S-Netze, Al/Cu, in Anlehnung an HD 603 S1 Teil 7E

BayEnergy® EMV++ Al/CuSM 3+1+1   3 Cu+1 Al+1 PE-adrig

BayEnergy® paper insulated cables

BayEnergy® Paper insulated cables, belted cable, copper acc. to DIN VDE 0276-621

NKBA   3-cores 6/10 kV       |       NKBY    3-cores 3,6/6 kV      3-cores 6/10 kV

BayEnergy® Paper insulated cables, 3-cores with single lead sheath, copper acc. to DIN VDE 0276-621

NEKEBA   3-cores 12/20 kV      3-cores 18/30 kV      3-cores 21/36 kV       |       NEKEBY    3-cores 12/20 kV    3-cores 18/30 kV      3-cores 21/36 kV

BayEnergy® Paper insulated cables, belted cable, aluminium acc. to DIN VDE 0276-621

NAKBA   3-cores 6/10 kV       |      NAKBY   3-cores 3,6/6 kV     3-cores 6/10 kV


BayEnergy® Paper insulated cables, 3-cores with single lead sheath, aluminium acc. to DIN VDE 0276-621

NAEKEBA    3-cores 12/20 kV     3-cores 18/30 kV      3-cores 21/36 kV        |      NAEKEBY    3-cores 12/20 kV     3-cores 18/30 kV     3-cores 21/36 kV

BayEnergy® grounding cables

highly flame retardant grounding cable mainly for outdoor use, especially for public transport with anti-theft design

BayEnergy® nonfire MetroSafe GC Al


grounding cable mainly for outdoor use, especially for public transport with anti-theft design

BayMotion® TramSafe GC AL


grounding cable mainly for outdoor use, with anti-theft design and released for use in the area of operation of Deutsche Bahn AG

BayEnergy® CPR (N)A(St)YY

BayEnergy® CPR (N)A(St)2XH (halogen-free)


grounding cable mainly for outdoor use, released for use in the area of operation of Deutsche Bahn AG

BayEnergy® CPR (N)AYY

highly flame retardant, theft defending flexible grounding cable for Indoor

BayMotion® nonfire MetroSafe GC


Theft defending flexible grounding cable for Outdoor

BayMotion® TramSafe GC 70


Theft defending grounding cable for Outdoor

BayMotion® TramSafe GC AL


Theft defending Aluminium grounding cable approved for use in systems of Deutsche Bahn AG

BayMotion® CPR (N)A(St)YY RF 0,6/1 kV


Theft defending grounding cable approved for use in systems of Deutsche Bahn AG

BayEnergy® (N)2X CuStAl


highly flame retardant, theft defending flexible grounding cable for Indoor

BayEnergy® (N)2X CuStAl FRNC B2


highly flame retardant, highly flexible wire for earthing and short-circuiting sets (EaS)

BayMotion® CPR H00V-D


highly flame retardant flexible grounding wire

BayMotion® nonfire (N)HA

Conductor ropes

Copper ropes, bare, uncompacted

BayEnergy® Cu-ropes RM

Copper ropes, bare, uncompacted, tinned

BayEnergy® Cu-ropes RM (vzn)

Copper ropes, bare, compacted

BayEnergy® Cu-ropes RMv

Copper ropes, bare, compacted, tinned

BayEnergy® Cu-ropes RMv (vzn)

Aluminium ropes, bare, compacted or uncompacted

BayEnergy® Al-ropes RM

Aluminium ropes for overhead lines acc. EN50182 – e.g. for railway overhead contact lines

BayEnergy® Al-rope for overhead lines typ AL1

Copper ropes with lead sheath

BaySpecial® NB

International power cables

acc. to international standards and specifications

Technical Information, Tables and Data

Here you will find general information, technical tables for electrical and mechanical characteristics, material tables, cable designation codes and further details about cables and wires.